34 found, showing page 1 of 3
112 3.5 OCT BX W/CLIP
With non-metallic sheathed cable clamps. Two 1/2" conduit knockouts and four cable knockouts, (sides). One 1/2" conduit knockout, (bottom). Octagon boxes can be used in the installation of ceiling or wall lighting fixtures or as a junction box. Not designed for ceiling fan support. 1-1/2" deep, 11.8 cubic inch capacity. UL Listed, acceptable for use in 2-hour fire rated walls.
- 3-1/2 Inch - Drawn Construction
- With Conduit & Cable Clamps
- Combination screw heads allow for fast cover or fixture installation
- Not designed for ceiling fan support
- Fire resistance: acceptable for use in 2 hr rated walls and ceilings
- Side knockout: (2) 1/2 in (4) Priouts, Bottom knockout: (1) 1/2 in
View Details
Call for Price
130 4" OCT EXTENSION
Two 1/2" and two 3/4" conduit knockouts (sides). Extension rings provide a means for adding additional cubic capacity or as and outlet box for surface conduit.
- 4 Inch - Extension Rings
- Drawn Construction
- 1-1/2" Deep - 15.5 Cubic Inches
View Details
Call for Price
150 4" OCTAGON BOX WITH EARS
With non-metallic sheathed cable clamps. With ear brackets. Two 1/2" conduit knockouts and four cable knockouts, (sides). One 1/2" conduit knockout, (bottom). Can be used in the installation of ceiling or wall lighting fixtures or as a junction box. Not designed for ceiling fan support. 50 pound maximum recommended static load. 1-1/2" deep, 15.5 cubic inch capacity. Acceptable for use in 2-hour fire rated walls. UL Listed.
- 4 Inch - Drawn Construction
- With Conduit & Cable Clamps
- Clamps for nonmetallic sheathed cable armored cable or flexible metal conduit
- Combination screw heads provide for faster installation
- Time-saving set-up boxes shorten installation time for lighting fixtures
- Non metal clamp ears
- Used in the installation of ceiling or wall lighting fixtures
- Offers a variety of labor saving mounting brackets that allow for easy positioning of box along studs or joists
- Support for fixtures up to 50 lb
- Combination screw heads allow for fast cover or fixture installation, adjustable plaster ears on each side
View Details
Call for Price
167 4" OCT BOX 2-1/8 DP
Two 1/2" and two 3/4" conduit knockouts (sides). Three 3/4" and two 1/2" conduit knockouts (bottom). No bracket. Can be used in the installation of ceiling or wall lighting fixtures or as a junction box. Not designed for ceiling fan support. 50 pound maximum recommended static load. Acceptable for use in 2-hour fire rated walls. UL Listed. UPC bar code.
- 4 Inch - Drawn Construction
- 2-1/8" Deep - 21.5 Cubic Inches
View Details
Call for Price
176 4" OCT BOX ROMEX
With non-metallic sheathed cable clamps. Two 1/2" conduit knockouts and four cable knockouts, (sides). One 1/2" conduit knockout, (bottom). Can be used in the installation of ceiling or wall lighting fixtures or as a junction box. Not designed for ceiling fan support. 50 pound maximum recommended static load. J side-mount bracket with spurs and holes for toe-nailing, for wood studs or joists. UPC bar code. UL Listed.
- 4 Inch - Drawn Construction
- With Cable Clamps & J Bracket
- 2-1/8" Deep - 21.5 Cubic Inches
- Combination screw heads allow for fast cover or fixture installation
- J bracket features nailing spurs, slotted holes for toe-nailing, and gauging notches at 3/8 in and 1/2 in
- Not designed for ceiling fan support
- Side knockout: (2) 1/2 in (4) Priouts, Bottom knockout: (1) 1/2 in
- Fire resistance: acceptable for use in 2 hr rated walls and ceilings
View Details
Call for Price
404 1" SW BOX W/BRKT
Shallow switch box, made for use with furring strips and 1/4" paneling. Welded, with nonmetallic sheathed cable clamps. Two cable knockouts (end). One 1/2"' conduit knockout (end). D bracket for wood or metal studs. 1/4" bracket setback. 1" deep - 6.5 cubic inches. UL Listed.
- Non-Gangable
- 3 Inch X 2 Inch
- Box features flat D bracket that is scored so bracket can be removed
- Shallow switch boxes are made for use with furring strips and 1/4 in paneling
- Fire resistance: acceptable for use in 2 hr rated walls
View Details
Call for Price
410 1.5" DP SWITCH BOX W/EAR
Four cable knockouts on the end. 3" x 2" x 1-1/2" deep. 7.5 cubic inches. With clamps for non-metallic sheathed cable. Plaster ears allow the box to be used in old work applications. Acceptable for use in 2-hour fire rated walls. UL Listed.
- Non-Gangable - Single Gang
- Old/New Work - With Ears
View Details
Call for Price
473 2.25" SWITCH BOX
Gangable 3" x 2" switch box, offers the option of constructing a box to hold two or more devices. Beveled corners prevent the clamp screws from protruding into the back wall. With nonmetallic sheathed cable clamps. Acceptable for use in 2-hour fire rated walls. Four cable knockouts (end). Two 1/2" conduit knockouts (end). 1/2" conduit knockouts (bottom). With leveling bumps. No plaster ears, not suitable for old work. 2-1/4" deep - 10.5 cubic inches. UL Listed.
- Single Gang - New Work
- Gangable
- Gangable switch box offers the option of constructing a box to hold two or more devices
- Beveled corner boxes are designed to prevent the clamp screws from protruding into back wall
- Leveling bumps allow box to be mounted flush to side of stud
- Acceptable for use in 2 hr fire rated wall
- Bottom knockout: (1) 1/2 in, End knockout: (2) 1/2 in, (4) Priouts
View Details
Call for Price
487 SWITCH BOX OLD WORK
Four cable knockouts (end). One 1/2" conduit knockout (bottom). Clamp screws through beveled corners. With clamps for non-metallic sheathed cable. Adjustable plaster ears allow box to be used in old work applications. Old work clips on side of box eliminates the need for additional box supports to secure box in wall opening. 3" x 2" x 2-1/4" deep. 10.5 cubic inches.
- Gangable - Old Work
- With Ears - 3 Inch X 2 Inch
- Gangable switch box offers the option of constructing a box to hold two or more devices
- Adjustable plaster ears allow box to be used in "old work" applications
- Provided old work clips on side of box eliminates the need for additional box supports to secure box in wall opening
- Beveled corner boxes are designed to prevent the clamp screws from protruding into back wall
- Fire resistance: acceptable for use in 2 hr rated walls
- Bottom knockout: (1) 1/2 in, End knockout: (4) Priouts
View Details
Call for Price
926 CEILING FAN BOX W/BRACE
Ceiling fan box with brace, 1-1/2" deep, 15.5 cubic inch box, for new work, to hang ceiling fans and light fixtures between joists or structural members safely and securely. Drawn construction. Maximum 70 pound fan or 90 pound fixture. Brace is adjustable form 16" to 24". Includes 2 end 1/2" knock outs. Acceptable for use in 2-hour fire rated walls and ceilings. UL Listed.
- Steel - Deep Round
- New Work
- Cu In Cap : 15.8
- For new work installations
- Brace is adjustable from 16 - 24 in joist spacing - simple tool free expansion
- High strength, hardened screws
- Knockouts in bottom of box allows for easy entry and exiting with cables
- Maximum support load for ceiling fans 70 lb and 210 lb at 16 in for static light fixtures
- Fire resistance: acceptable for use in 2 hr rated walls and ceilings
View Details
Call for Price
175 4" OCT BOX W/EARS
With non-metallic sheathed cable clamps. Two 1/2" conduit knockouts and four cable knockouts, (sides). One 1/2" conduit knockout, (bottom). Can be used in the installation of ceiling or wall lighting fixtures or as a junction box. Not designed for ceiling fan support. 50 pound maximum recommended static load. 2-1/8" deep, 21.5 cubic inch capacity. UL Listed.
- 4 Inch - Drawn Construction
- With Conduit & Cable Clamps
- Combination screw heads allow for fast cover or fixture installation
- Not designed for ceiling fan support
- Fire resistance: acceptable for use in 2 hr rated walls and ceilings
- Side knockout: (2) 1/2 in (4) Priouts, Bottom knockout: (1) 1/2 in
View Details
Call for Price
8125 4" OCT BX 1/2KO'S
Hubbell Octagon Box, Hubbell, 1 Gangs, 9 Knockouts, 1/2 in Knockout, Non-Metallic Sheathed Cable Clamp Cable Entry, 4 in Length, 4 in Width, 1-1/2 in Depth, 15 cu-in Capacity, Steel, Grey, UL Listed, Used in the Installation of Ceiling or Wall Lighting Fixtures or as a Junction Box
View Details
Call for Price
8127 4" OCT BX 3/4KO'S
Two 1/2" and two 3/4" conduit knockouts (sides). Two 1/2" and two 3/4" conduit knockouts (bottom). No bracket. Can be used in the installation of ceiling or wall lighting fixtures or as a junction box. Not designed for ceiling fan support. 50 pound maximum recommended static load. Acceptable for use in 2-hour fire rated walls. UL Listed.
- 4 Inch - Drawn Construction
- 1-1/2" Deep - 15.5 Cubic Inches
View Details
Call for Price
8146 4" OCT BX-1.5"DP
With non-metallic sheathed cable clamps. Two 1/2" conduit knockouts and four cable knockouts, (sides). One 1/2" conduit knockout, (bottom). Used in the installation of ceiling or wall lighting fixtures or as a junction box. 1-1/2" deep, 15.5 cubic inch capacity. 50 pound maximum recommended static load. Not designed for ceiling fan support. Acceptable for use in 2-hour fire rated walls. UL Listed. UPC bar code.
- 4 Inch - Drawn Construction
- With Conduit & Cable Clamps
View Details
Call for Price
8160 4" OCT BOX ROMEX
With non-metallic sheathed cable clamps. Two 1/2" conduit knockouts and four cable knockouts, (sides). One 1/2" conduit knockout, (bottom). Can be used in the installation of ceiling or wall lighting fixtures or as a junction box. Not designed for ceiling fan support. 50 pound maximum recommended static load. J side-mount bracket with spurs and holes for toe-nailing, for wood studs or joists. UPC bar code. UL Listed.
- 4 Inch - Drawn Construction
- With Cable Clamps & J Bracket
- 1-1/2" Deep - 15.5 Cubic Inches
View Details
Call for Price